Output elements
| |
Secure moving parts against ejection Make sure there are no moving parts on or in the machine during operation. Feather keys [+] are only secured during transport. Unsecured parts can be ejected from the machine during operation and cause serious or fatal injuries. |
Notice | |
Protect the motor from inadmissible load Avoid bending components during transport or handling and do not change any insulation distances. Avoid hard shocks to the shaft end, the ball bearings or the feedback system. Furthermore, note vibration qualities and vibration resistance. If necessary, provide additional support for the motor. An impermissible load on the components can have a negative effect on the performance of the motor. Impacts on the motor shaft impair the concentricity of the motor. |
Notice | |
Ensure adequate grounding via the protective conductor The thermal connection of the motor flange determines the power dissipation. Ensure adequate grounding via the protective conductor or the motor flange. |
Clamping sets are used to fasten pulleys, gears or couplings to the motor shaft. The outer cone and the inner cone are axially displaced against each other. This process reduces the inner diameter of the bore and increases the outer diameter.
