Long-term storage
Notice | |
Observe the maximum storage time Do not exceed the maximum storage time of two years. Exceeding the specified maximum storage time can lead to changes in the properties of the lubricant used and damage the motor during subsequent operation. |
Notice | |
Perform recurring inspections Check the motor for proper condition every six months. Damage to the motor or maintenance work not carried out will affect the service life of the installed components and parts. |
Notice | |
Prevent the formation of condensation Keep the ambient temperature constant. Avoid solar radiation and high humidity. Condensation water can lead to damage during subsequent operation or to rust formation. |
The motors can be stored for shorter or longer periods. For storage we always recommend the original packaging. Adhere to the conditions specified in the chapter: Transport and storage.
The motors are protected against chemical and aggressive substances, class 1C2, chemical substances and 1B2, biological conditions.
Ensure the storage space is vibration-free.