Guide for commissioning

The procedure for commissioning is described as an example.

A different method may be appropriate or necessary, depending on the application of the equipment.

 

  • Check the assembly and orientation of the motor.
  • Check the drive components (coupling, gear unit, pulley) for the correct seating and setting (observe the permissible radial and axial forces).
  • Check the wiring and connections to the motor and the servo drive. Check that the earthing is correct.
  • Check whether the rotor of the motor revolves freely (release the brake, if necessary). Listen out for grinding noises.
  • Check that all the required measures against accidental contact with live and moving parts have been carried out.
  • Carry out any further tests which are specifically required for your system.
  • Now commission the motor according to the commissioning instructions.