General technical data
|
Insulation class |
Class B (130°C) according to IEC60085 |
|
Temperature change at rated current |
Max. 80 K |
|
Insulation resistance |
≥ 100 MΩ |
|
Permissible ambient temperature (operation) |
-10 °C to +50 °C |
|
Permissible ambient temperature (transport/storage) |
-25 ℃ to +70 ℃ |
|
Permissible air humidity |
20% to 90%, non-condensing |
|
Permissible level of contamination |
Contamination level 2 according to EN60204/EN50178 |
|
Corrosion protection |
Under extreme operating conditions, special measures must be agreed with the manufacturer, and implemented by the user. |
|
Permissible operating altitude |
Up to 1000 m above sea level |
|
Maximum cable length between motor and terminal |
10 m |
|
Special operating conditions |
The applicability of the Beckhoff AS1000 stepper motor is to be determined for each individual case. Application in harsh operating or environmental conditions requires coordination between manufacturer and user. |
|
Correct installation position |
Horizontal or vertical |
|
Ventilation |
Ensure adequate ventilation of the motors. |
|
Protection class (doesn´t apply to the shaft bushing) |
AS1010 – AS1050: IP43 |