ST_ArtPOLLREPLY_Frame
TYPE ST_ArtPOLLREPLY_Frame:
STRUCT
aPreamble : ARRAY [0..7] OF BYTE; (*'Art-Net' 0x00*)
aOpCode : ARRAY [0..1] OF BYTE; (*OpDmx,transmitted low byte first – see E_ArtNet_OpCodes*)
aIP : ARRAY [0..3] OF BYTE; (*Array containing the Node’s IP address*)
aPort : ARRAY [0..1] OF BYTE; (*The value of the used UDP Port, should always be 0x1936, transmitted low byte first.*)
aVersionInfo : ARRAY [0..1] OF BYTE; (*Node’s firmware revision number.*)
nNetSwitch : BYTE; (*Bits 14-8 of the 15 bit Port-Address are encoded into the bottom 7 bits of this field.*)
nSubSwitch : BYTE; (*Bits 7-4 of the 15 bit Port-Address are encoded into the bottom 4 bits of this field.*)
aOem : ARRAY [0..1] OF BYTE; (*The Oem describes the equipment vendor*)
nUbeaVersion : ARRAY [0..1] OF BYTE; (*This field contains the firmware version of the User Bios Extension Area (UBEA).)
nStatus1 : BYTE; (*General Status register*)
nESTA : ARRAY [0..1] OF BYTE; (*The ESTA manufacturer code*)
aShortName : ARRAY [0..17] OF BYTE; (*Node’s short name*)
aLongName : ARRAY [0..63] OF BYTE; (*Node’s long name*)
aNumPorts : ARRAY [0..1] OF BYTE; (*The low byte describing the number of input or output ports. The maximum value is 4.*)
aPortTypes : ARRAY [0..3] OF BYTE; (*This array defines the operation and protocol of each channel.*)
aGoodInput : ARRAY [0..3] OF BYTE; (*This array defines input status of the node.*)
aGoodOutput : ARRAY [0..3] OF BYTE; (*This array defines output status of the node.*)
aSwIn : ARRAY [0..3] OF BYTE; (*Bits 3-0 of the 15 bit Port-Address for each of the 4 possible input ports are encoded into the low nibble.*)
aSwOut : ARRAY [0..3] OF BYTE; (*Bits 3-0 of the 15 bit Port-Address for each of the 4 possible output ports are encoded into the low nibble.*)
nSwVideo : BYTE; (*Set to 00 when video display is showing local data. Set to 01 when video is showing ethernet data.*)
nSwMacro : BYTE; (*If the Node supports macro key inputs, this byte represents the trigger values.*)
nSwRemote : BYTE; (*If the Node supports remote trigger inputs, this byte represents the trigger values.*)
aSpare : ARRAY [0..2] OF BYTE;
nStyle : BYTE; (*The Style code defines the equipment style of the device.*)
aMAC : ARRAY [0..5] OF BYTE; (*Node’s MAC-Address*)
aBindIP : ARRAY [0..3] OF BYTE; (*If this unit is part of a larger or modular product, this is the IP of the root device.*)
nBindIndex : BYTE; (*Set to zero if no binding, otherwise this number represents the order of bound devices*)
nStatus2 : BYTE; (*Status register*)
END_STRUCT
END_TYPEThis structure is used for sending and receiving PollRepl-' telegrams. It matches the telegram described in the Art-Net™ specification (www.Art-Net.org.uk) under 'ArtPOLLREPLY'.