63B7, Modulo calculation primary feedback: The absolute range of encoder is too small or incompatible
Modulo calculation primary feedback: The absolute range of encoder is too small.
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
63B7 |
25527 |
Class |
Type |
---|---|
Error |
Error |
Standard Reaction |
Reset |
---|---|
Axis is inoperable |
Execute Reset-Command (Fault reset). |
Possible Causes |
Solutions |
---|---|
The modulo calculation with data storage can only be used if a multi-turn feedback is connected. |
Connect and use a multi-turn feedback. |
The modulo calculation with data storage can only be used if a rotary feedback is connected. |
Connect and use a rotary feedback and motor. |
Internal: 0x63B7, Modulo calculation primary feedback: The absolute range of encoder is too small or incompatible