Power supply modules and coupling modules

►Screw the screws into the mounting plate on the machine or plant as shown in the drilling pattern
Power supply modules and coupling modules 1:
►Place the power supply module [1] onto the screw [2] and carefully press against the mounting plate [3]
Power supply modules and coupling modules 2:
►Guide the screws [1] through the rectangular cut-outs in the module housing [2]
►Screw all the screws tight in the elongated holes in the module housing
►Observe tightening torques:

Components

Tightening torque [Nm]

Screws M5 x 5
Strength class 8.8

6

Power supply modules and coupling modules 3:
►On all relevant modules, slide the bar for the AX bridge [1] to the right

The contacts can then no longer be seen.

►Screw the screws back into the mounting plate of the machine or plant as shown in the drilling pattern
Power supply modules and coupling modules 4:
►Place the coupling module [1] at the right side of the coupling module [2] onto the screw [3] and carefully press against the mounting plate [4]
Power supply modules and coupling modules 5:
►Once again, guide the screws [1] through the rectangular cut-outs in the module housing [2]
Power supply modules and coupling modules 6:
►Make sure that the plates of the rear panel of Module [1] are not overlapping and that the modules are sitting flush in cut-out [2]
►Bay further modules and screw all remaining screws tight on the module housings
►Observe tightening torques:

Components

Tightening torque [Nm]

Screws M5 x 5
Strength class 8.8

6

Power supply modules and coupling modules 7:
►On all modules that you wish to connect, open the quick connectors [1] and place them in the 90° position
Power supply modules and coupling modules 8:
►Slide all bars [2] for the AX bridge to the left
►Close all quick connectors again

The modules are now connected to one another.