Power supply modules and coupling modules

Screw the screws into the mounting plate on the machine or plant as shown in the drilling pattern
Power supply modules and coupling modules 1:
Place the power supply module [1] onto the screw [2] and carefully press against the mounting plate [3]
Power supply modules and coupling modules 2:
Guide the screws [1] through the rectangular cut-outs in the module housing [2]
Screw all the screws tight in the elongated holes in the module housing
Observe tightening torques:

Components

Tightening torque [Nm]

Screws M5 x 5
Strength class 8.8

6

Power supply modules and coupling modules 3:
On all relevant modules, slide the bar for the AX bridge [1] to the right

The contacts can then no longer be seen.

Screw the screws back into the mounting plate of the machine or plant as shown in the drilling pattern
Power supply modules and coupling modules 4:
Place the coupling module [1] at the right side of the coupling module [2] onto the screw [3] and carefully press against the mounting plate [4]
Power supply modules and coupling modules 5:
Once again, guide the screws [1] through the rectangular cut-outs in the module housing [2]
Power supply modules and coupling modules 6:
Make sure that the plates of the rear panel of Module [1] are not overlapping and that the modules are sitting flush in cut-out [2]
Bay further modules and screw all remaining screws tight on the module housings
Observe tightening torques:

Components

Tightening torque [Nm]

Screws M5 x 5
Strength class 8.8

6

Power supply modules and coupling modules 7:
On all modules that you wish to connect, open the quick connectors [1] and place them in the 90° position
Power supply modules and coupling modules 8:
Slide all bars [2] for the AX bridge to the left
Close all quick connectors again

The modules are now connected to one another.