Before commissioning

Notice

Limited functionality due to unformed capacitors

The dielectric in the DC link capacitors decreases over a very long storage period and the capacitors lose their forming. This can lead to considerable functional restrictions and even a shortened service life of the device.

  • If the storage period exceeds 5 years, form the capacitors

Pay attention to the following points before commissioning:

 

Before commissioning 1:

Installing the M8 jumper plug on the AMP8xxx-xxx2

Before commissioning, the supplied M8 jumper plug [3] must be installed on the M8 connection [1] with 0.4 Nm to establish the electrical connection between the motor electronics and the holding brake.

Also make sure to use the tamper protection [2] according to the chapter Activation of the holding brake for service purposes.