During operation

Observe the discharge times of the capacitors

Observe the following delay times after disconnecting from the mains supply:

  • AMP8yxx

30 minutes

  • AX883x

30 minutes

 

Do not work on live electrical parts

Only work on the distributed servo drive system when the voltage has dropped to < 50 V. Measure the voltage and observe the waiting times. Ensure that the protective conductor is connected properly. Never loosen electrical connections when live. Disconnect all components from the mains and secure them against being switched on again.

Do not touch hot surfaces

Check the temperature of the surfaces with a thermometer. Do not touch the components during and immediately after operation. Allow the components to cool sufficiently after switching off.

Avoid overheating

Operate the components according to the technical specifications. Refer here to the chapter Technical data. Provide for sufficient cooling. Switch the components off immediately if the temperature is too high.

Do not touch any moving or rotating components

Do not touch any moving or rotating components. Fasten all parts or components on the machine or plant.