Intervals

Under nominal conditions, the motor components have different operating hours. We have provided you with a list of maintenance work and intervals for the associated components below:

Component

Interval

Maintenance

Ball bearing

30000 operating hours

Replace bearing

Servo drive

2500 operating hours/annually

Check servo drive for bearing noises

If noises are detected:

  • Do not continue to operate the servo drive; replace bearing

Shaft sealing ring

5000 operating hours

Perform visual inspection

Lubricate the shaft sealing ring

Recommended lubricants:

  • MobilgreaseTM FM22“ from Mobil

In case of damage and pressure drop:

  • Replace shaft sealing ring

Cables

Regular intervals

Perform visual inspection and check for damage

If required:

  • Replace cables

5 million bending cycles

Replace cables

Sockets

500 cycles

In case of damage:

  • Contact Beckhoff Service