AM812x
Electrical data  | AM81xx  | ||||||
|---|---|---|---|---|---|---|---|
21F  | 21F on EL7201  | 22F  | 22F on EL7201  | 22J  | 22N  | 23N  | |
  | 0.5  | 0.35  | 0.8  | 0.56  | 0.8  | 0.8  | 1.2  | 
  | 4.0  | 2.8  | 4.0  | 2.8  | 8.0  | 13.5  | 15.3  | 
  | 12000  | 12000  | 12000  | 12000  | 12000  | 12000  | 12000  | 
  | 50  | 50  | 50  | 50  | 50  | 50  | 50  | 
  | 17  | 5.66  | 22.4  | 5.66  | 48  | 86.6  | 88.4  | 
  | 1.97  | 0.69  | 4.06  | 1.09  | 4.06  | 4.18  | 6.37  | 
  | 0.125  | 0.125  | 0.2  | 0.2  | 0.1  | 0.059  | 0.078  | 
  | 8  | 8  | 13  | 13  | 6  | 3.5  | 5.5  | 
  | 1.6  | 1.6  | 1.5  | 1.5  | 0.34  | 0.138  | 0.14  | 
  | 2.8  | 2.8  | 3.3  | 3.3  | 0.7  | 0.24  | 0.35  | 
Power supply UN= 24 V DC  | |||||||
  | 1000  | 1000  | 600  | 600  | 2000  | 3500  | 2000  | 
  | 0.5  | 0.35  | 0.8  | 0.56  | 0.78  | 0.75  | 1.2  | 
  | 52  | 36  | 50  | 35  | 163  | 275  | 251  | 
Power supply UN= 48 V DC  | |||||||
  | 3000  | 3000  | 2000  | 2000  | 4500  | 8000  | 5000  | 
  | 0.5  | 0.35  | 0.8  | 0.56  | 0.75  | 0.7  | 1.1  | 
  | 157  | 110  | 167  | 117  | 353  | 586  | 576  | 
  | 4  | 2.8  | 4  | 2.8  | 8  | 12.5  | 14.6  | 
Connection technology  | iTec  | iTec  | iTec  | iTec  | iTec  | M23-Speedtec  | M23-Speedtec  | 
Reference flange aluminum 230 mm x 130 mm x 10 mm Installation of a shaft seal ring leads to a reduction of the rated values.  | |||||||
Mechanical data  | AM81xx  | ||
|---|---|---|---|
21  | 22  | 23  | |
  | 0.134  | 0.26  | 0.38  | 
  | 0.204  | 0.33  | 0.45  | 
  | 6  | ||
  | 0.002  | 0.004  | 0.006  | 
  | 10  | 13  | 16  | 
  | 1.00  | 1.3  | 1.7  | 
  | 1.16  | 1.66  | 1.96  | 
Flange  | |||
  | j6  | ||
  | N  | ||
Protection class  | |||
  | IP54  | ||
  | IP54  | ||
Paint finishes  | |||
  | acrylic powder-coated  | ||
  | Anthracite gray; RAL 7016  | ||
Optional holding brake [+]  | AM812x  | 
|---|---|
  | 2  | 
  | 24;+6 % to -10 %  | 
  | 10  | 
  | 0.3  | 
  | 25  | 
  | 8  |