Holding brake
The motors can be equipped as an option with permanent magnet holding brakes. These operate according to the quiescent current principle and open at a voltage of 24 VDC +6 / -10 % with > 10,000,000 switching cycles.
The holding brake installed is not suitable for service braking because there is no monitoring for wear and functionality by the servo terminal and configuration. This applies in particular to vertical axes.
![]() | Safety measures for vertical axes must be applied When operating vertical axes, appropriate additional measures must be taken; for example, including but not only:
|
A holding brake blocks the rotor in the de-energized state. The holding brake increases the motor length and the rotor moment of inertia. The holding brake cannot be retrofitted and is mounted on the B bearing side of the motor.