Mounting
Notice | |
Clean the working environment Workplaces and their immediate surroundings must be tidy and dust-free. Avoid dirt in tapped holes. Disregarding this can lead to malfunctions and damage to the components. |
- ►Attach the motor to the machine
Only for AM807x series:
- ►If necessary, loosen and remove the eyebolts on the motor housing
- ►Push the fan cover [+] [1] up to the mechanical stop
- ►Make sure that on both sides of the motor the elongated holes [3] are aligned with the screw connection devices [2]
- ►Fit screws [4] to [7]
- ►Fit nuts [8] and [11] with washers [9] and [10]
- ►Observe tightening torques:
Screws | Nuts |
|---|---|
3 Nm size 2.5 | 2.5 Nm, size 7 |
Use Beckhoff control cable
Use the pre-assembled control cable ZK4054-6400-0xxx to connect the fan cover [+]
- ►Plug the power connector [12] into the power box [13] of the motor
- ►Hand-tighten power connector [12] and check for tight fit