Before commissioning

Pay attention to the following points before commissioning:

►In the case of multi-axis systems, commission each drive unit separately
►Read the operating instructions for the servo drive
►Check drive for damage
►Check mounting and alignment
►Tighten screw connections correctly
►Installing mechanical, thermal and electrical protective devices
►Check the wiring, connection and proper grounding of the
drive and servo drive

In case of motors with holding brake [+]

►Check the function of the holding brake [+]
►In case of malfunction: apply 24 VDC, release brake
►Check emergency stop functions

In case of motors with fan cover [+]

►Check connection and function
►Fan must rotate freely, pay attention to grinding noises
►Check the direction of rotation of the fan