Overall mounting height
You can increase the overall mounting height and the associated air gap in case of tolerance deviations. Tolerance deviations can result from:
- deviations in parallelism or
- deviations in the evenness of the mounting surface
![]() | Be aware of performance losses with increased air gap Increasing the overall mounting height or the air gap may have performance implications. These follow a non-linear function. Please refer to the diagram in Chapter: Dependencies. Avoid reducing the air gap Reducing the air gap increases the forces of magnetic attraction between the coil part and the magnetic track. This requires larger guides and a stiffer design of the machine or system. |
The following table and figure provide information about the overall mounting heights of the individual series:
Series | Mounting height "X" [mm] |
|---|---|
AL812x | 40 ± 0.1 |
Position | Description |
|---|---|
1 | Machine slide |
2 | Coil part |
3 | Magnetic plate |
4 | Machine bed |