Conventional calculation

In a conventional calculation, the length of the coil unit is added to the travel path of the application and then divided by the length of the magnetic plate.

Conventional calculation 1:

Example for conventional calculation:

Travel path = 490 mm

Length of coil unit AL8121 = 93 mm

Length of magnetic plate AL8523 = 384 mm

 

Required number of magnetic plates:

(490 mm + 93 mm)/384 = 1.52 magnetic plates < 2 magnetic plates are required.