Magnetic plates
| |
Danger from strong magnetic fields Strong permanent magnets generate intense magnetic fields that can interfere with or disable the function of pacemakers. This can cause serious health problems, including unconsciousness, heart attack or even death.
|
| |
Serious injuries due to magnetic forces of attraction Severe crushing injuries may result if the strong magnetic field of the permanent magnets in the magnetic plate unexpectedly attracts the components magnetically during assembly. The cover weakens the magnetic field and protects electrical components from magnetic influences.
|
![]() | Defective smartphones and smartwatches due to strong magnetic fields Strong magnetic fields emitted by magnetic plates can negatively affect devices such as smartwatches and smartphones.
|
![]() | Observe the alignment Align the magnetic plates identically. The Beckhoff logo must always be on the same side. If this is not observed, the adjacent magnetic plates repel each other. As a result, the coil unit cannot move without restriction. The system is not operational. |
![]() | Observe minimum gap Keep the required minimum gap when mounting additional magnetic plates. This is 48 mm between hole centers. During mounting, maintain a distance of at least 10 cm between the magnetic plate to be mounted and the mechanically protected coil unit. Failure to observe this can lead to complications during installation. |
![]() | Minimum gap (example) The diagram shows the minimum gap between two magnetic plates. |
- Distance between hole centers: 48 mm
Mounting
| |
Serious injuries due to uncontrolled movement of the machine carriage If the strong magnetic field of the permanent magnets in the magnetic plate unexpectedly attracts the components magnetically during assembly, it is not possible to hold the machine carriage by hand. Severe injuries to limbs can be the result.
|
- ►Clean the mounting surface on the machine bed and the magnetic plate
- ►Push the machine carriage [1] to one end of the machine bed [2]
- ►Mechanically secure the machine carriage against the forces of attraction and uncontrolled movements of the magnetic plate
- ►Insert locating pins [3] into the machine bed
- ►Pay attention to the insertion depth of the locating pins [3]
Locating pins | AL852x | AL854x | AL856x |
|---|---|---|---|
Tolerance zone | M6 | ||
Maximum immersion in the magnetic plate [mm] | 3.2 | 5.5 | |
- ►Check the alignment of the magnetic plate. Make sure that the Beckhoff logos are on the same side.
- ►Place the magnetic plate [4] on the locating pins [3]
- ►Insert screws [5] into the magnetic plate on the machine bed
- ►Tighten the screws crosswise and from inside to outside
Observe tightening torque:
Screw quality = strength class 8.8 | |
|---|---|
Screw | M5 |
Tightening torque [Nm] | 6 |
![]() | These steps must be repeated until half of the travel path has been fitted with magnetic plates. |
- ►Remove the protective cover [6] on the mounted magnetic plates onto which the machine carriage is to be pushed. Do not dispose of the protective cover and keep it for subsequent transport of the machine or system.
Other magnetic plates
- ►Push the machine carriage [1] onto the mounted magnetic plates [2]
- ►Secure the machine carriage mechanically against uncontrolled movements
- ►Mount the other magnetic plates in the same way
Once all components have been fitted and you start the machine or system:
- ►Remove all protective covers [3] on all magnetic plates


