Disassembly
WARNING | |
Risk of injury during disassembly Permanent magnets are installed in the AL85xx magnetic plates. Carefully remove the magnetic plates. Make sure that the magnetic plates and ferromagnetic objects are not magnetically attracted and that your hands are not between these components. If you don't take care during the disassembly, opposite magnetic plates may attract each other without warning and injure your hands. |
Removing the magnetic plates from the machine:
- Push the machine slide to one side and mechanically secure it against uncontrolled movements
- Attach protective covers to the magnetic plates. The protective cover is included with the magnetic plates.
- Unscrew and remove the bolts
- Remove the magnetic plate
- Remove the locating pin
- Push the machine slide to the other side and mechanically secure it against uncontrolled movements
- Remove the other magnetic plates in the same way
Removing the coil part from the machine:
- If present: Remove the water cooling
- Disconnect the electrical connector
- Remove the machine slide from guide rails
- Unscrew and remove the bolts
- Separate the coil part from the machine slide
- Remove the locating pins