Disassembly

WARNING

Risk of injury during disassembly of the magnetic plates

Permanent magnets are installed in the AL85xx magnetic plates. During disassembly, the opposing magnetic plates can attract each other unpredictably due to the strong magnetic forces and injure your hands.

  • Carefully remove the magnetic plates
  • Make sure that your hands are not between the magnetic plates and ferromagnetic objects during disassembly

Removing the magnetic plates from the machine:

►Push the machine carriage to one side and mechanically secure it against uncontrolled movements
►Attach protective covers to the magnetic plates. The protective cover is included with the magnetic plates.
►Unscrew and remove the bolts
►Remove the magnetic plate
►Remove the locating pin
►Push the machine carriage to the other side and mechanically secure it against uncontrolled movements
►Remove the other magnetic plates in the same way

Removing the coil unit from the machine:

►If present: remove water cooling
►Disconnect the electrical connectors
►Remove the machine carriage from guide rails
►Unscrew and remove the bolts
►Separate the coil unit from the machine carriage
►Remove the locating pins