LPTC-600 sensor

The following table shows the resistance values of the temperature sensor:

Temperature [°C]

LPTC-600

Resistance [Ω]

Temperature error [K]

minimum

Nominal value

maximum

-40

340

359

379

± 6.48

-30

370

391

411

± 6.36

-20

403

424

446

± 6.26

-10

437

460

483

± 6.16

0

474

498

522

± 6.07

10

514

538

563

± 5.98

20

555

581

607

± 5.89

25

577

603

629

± 5.84

30

599

626

652

± 5.79

40

645

672

700

± 5.69

50

694

722

750

± 5.59

60

744

773

801

± 5.47

70

797

826

855

± 5.34

80

852

882

912

± 5.21

90

910

940

970

± 5.06

100

970

1000

1030

± 4.90

110

1029

1062

1096

± 5.31

120

1089

1127

1164

± 5.73

130

1152

1194

1235

± 6.17

140

1216

1262

1309

± 6.63

150

1282

1334

1385

± 7.10

160

1350

1407

1463

± 7.59

170

1420

1482

1544

± 8.10

180

1492

1560

1628

± 8.62