AL38xx
Technical data | AL3803 | AL3806 | AL3809 | AL3812 | AL3818 |
|---|---|---|---|---|---|
Winding type | N / S | N / S | N / S | N / S | N / - |
Velocity (max.) | 2.7 m/s (N) | 2.7 m/s (N) | 2.7 m/s (N) | 2.7 m/s (N) | 2.7 m/s (N) |
Motor configuration | 3-phase synchronous linear motors (230 V AC) | ||||
Peak force 3 s (FP) | 700 N | 1400 N | 2100 N | 2800 N | 4200 N |
Peak current (IPa) | 5.6 A (N), | 11.3 A (N), | 16.9 A (N), | 22.6 A (N), | 34 A (N) |
Continuous force with air cooling (Fca) | 141 N | 282 N | 423 N | 564 N | 846 N |
Continuous current (Ica) | 1.14 A (N) | 2.27 A (N), | 3.4 A (N), | 4.5 A (N), | 6.8 A (N) |
Continuous power loss (Pca) | 82 W | 165 W | 247 N | 330 W | 494 W |
Power constant (Kf) | 124 N/A (N), | 124 N/A (N) | |||
Motor constant (Km) | 323 N²/W | 647 N²/W | 970 N²/W | 1293 N²/W | 1940 N²/W |
Pole spacing | 57 mm | ||||
Winding resistance Ph-Ph (Rf) | 31.6 Ω (N), | 15.8 Ω (N), | 10.6 Ω (N), | 8 Ω (N), | 5.2 Ω (N) |
Winding inductance Ph-Ph (Lf) | 56 mH (N), | 28 mH (N), | 18 mH (N), | 14 mH (N), | 9.4 mH (N) |
Thermal resistance (Rth) | 1.04 °C/W | 0.52 °C/W | 0.35 °C/W | 0.26 °C/W | 0.17 °C/W |
Magnetic attractive force (Fa) | 0 N | ||||
Weight of the coil unit (Mp) | 0.55 kg | 0.95 kg | 1.35 kg | 1.75 kg | 2.55 kg |
Temperature sensor | PTC 1 kΩ | ||||
Suitable servo drive | AX5x03 (N) | AX5x06 (N), | AX5112 (N), | AX5112 (N), | AX5118 (N) |
cable length not assembled | 1 m | ||||
Minimum static bending radius | 4 x cable diameter | ||||
Power cable outside diameter | 6.40 mm | ||||
Power cable configuration | 4 x 0.82 mm² | ||||
Sensor cable outside diameter | 4.3 mm | ||||
Sensor cable configuration | 4 x 0.14 mm² | ||||