Mounting the magnet yokes
Note
Damage due to contamination
The mounting surface must always be free from contamination. Particles with a size of more than 0.1 mm can result in incorrect configuration and damage to your linear motor.
Start the assembly with yoke 1. Align yoke with 3 mm alignment pins or a milling reference. Mount the magnet yokes on the support frames. Observe the maximum tightening torque
An axis reference for the magnetic yokes is achieved as follows:
- Alignment pins in the center yoke (for short distances)
- Alignment pins along the entire path (for longer distances)
- Milling reference along the entire path (inside radius < 0.2 mm) for longer distances
The other magnet yokes can then be mounted, whereby the mutual attractive force of the magnet yokes can be controlled and utilized for the mechanical contact.