Dismantling sequence
WARNING | |
Damage due to uncontrolled magnetic attractive forces The dismantling sequence given in these instructions must be followed. A different sequence can give rise to dangerous situations, and can lead to damage resulting from uncontrolled magnetic attraction. |
Dismantling sequence:
- Check that there is no voltage and secure against being switched on again.
- Disconnect the electrical cables.
- Disconnect the hoses of the water cooling unit (if installed).
- Move the carriage to one side. Secure the carriage in such a way as to prevent unwanted movement.
- Cover each magnetic plate that needs to be removed with a neutralizing protective plate.
- Remove one or more magnetic plates. The distance between the magnetic plates and the coil unit or other exposed ferromagnetic parts should be no less than 10 cm.
- Move the carriage to the other side. Secure the carriage in such a way as to prevent unwanted movement.
- Cover each magnetic plate that needs to be removed with a neutralizing protective plate.
- Remove the remaining magnetic plates.
- Remove the coil unit from the carriage.