Important notes
Installation of the machine bed must be complete before installing the linear motor components. The rails must be mounted on the machine bed and aligned. The carriage must be equipped with bearings, dampers and the required lines so that the proper movement of the carriage over the track is ensured.
WARNING | |
Damage due to uncontrolled magnetic attractive forces The sequence specified in this introduction for the installation must be followed. A different sequence can give rise to dangerous situations, and can lead to damage resulting from uncontrolled magnetic attraction. |
Damage due to faulty water cooling unit If a water cooling unit is to be used, read please the section entitled Installation of the water cooling. |
NOTICE | ||
Deadly danger due to the magnetic fields of the linear motor! The AL2xxx linear motors are equipped with permanent magnets in the magnetic plate. Strong magnetic fields are present here. In the power-off state, the magnetic field strength of the motors results exclusively from the magnetic fields of the secondary part. There is a particular danger for: people fitted with cardiac pacemakers People with implanted defibrillators |
Note | |
Loss of data due to magnetic fields! -- Magnetic data storage devices -- Chip cards with magnetic strips and -- Electronic devices can be demagnetized by magnetic fields. The objects listed above and loose-lying ferromagnetic objects may not be brought any closer than 1 m to the magnetic plates. |
CAUTION | |
Damage due to a magnetic field that is not neutralized Use the magnetic plates only when they are covered by the protective plates that reduce the magnetic field. |
CAUTION | |
Damage during dismantling due to the magnetic field Make sure that the magnetic plates are fastened in your machine before removing the protective plates. |