Magnetic Encoder System (MES) (optional)
The Magnetic Encoder System (MES) AL2200-000y is a position measuring system. It has an accuracy of 0.1 mm and works directly on the magnetic plates. There are no further measuring scales. Fastening takes place on the carriage.
Description of the position measuring system | |
The MES works absolute within the pole distance (24 mm) and semi-absolute over the entire track. The distance to the coil part is not relevant. The commutation angle is determined once during commissioning. The wake & shake at the start of the machine is thus dispensed with. Homing can be carried out if an absolute synchronization is desired. | |
|
|
![]() | Documentation for the Magnetic Encoder System (MES)! Further information on the Magnetic Encoder System (MES) can be found on the Beckhoff homepage under: MES Feedback Documentation or in the Beckhoff Online Information System. |