NPT035 MA
Mechanical data | 1-stage | 2-stage | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
| 3 | 4 | 9 | 12 | 15 | 16 | 20 | 28 | 30 | 40 |
| 97 | 95 | ||||||||
| ≤ 65 | ≤ 61 | ||||||||
| > 20000 | |||||||||
| 9.4 | 9.8 | ||||||||
Mass moment of inertia J1 [kgcm²]
| ||||||||||
| --- | --- | 0.68 | 0.63 | 0.62 | 0.45 | 0.44 | 0.38 | 0.52 | 0.37 |
| --- | --- | 0.82 | 0.78 | 0.77 | 0.6 | 0.58 | 0.51 | 0.67 | 0.52 |
| 3.2 | 2 | 0.91 | 0.87 | 0.86 | 0.69 | 0.67 | 0.61 | 0.76 | 0.6 |
| 4 | 2.8 | 1.9 | 1.9 | 1.9 | 1.7 | 1.7 | 1.6 | 1.8 | 1.6 |
| 3.7 | 2.5 | 1.7 | 1.6 | 1.6 | 1.4 | 1.4 | 1.4 | 1.5 | 1.3 |
| 7.7 | 6.6 | --- | --- | --- | --- | --- | --- | --- | --- |
| 8.9 | 7.8 | --- | --- | --- | --- | --- | --- | --- | --- |
Torques and speeds | ||||||||||
| 380 | |||||||||
| 155 | 155 | 155 | 150 | 155 | 155 | 155 | 137 | 155 | 155 |
| 305 | 305 | 305 | 305 | 300 | 305 | 305 | 305 | 270 | 305 |
| 480 | |||||||||
| 2300 | 2500 | 3100 | 3300 | 3400 | 3300 | 3400 | 3600 | 3900 | 3900 |
| 6000 | 7000 | ||||||||
| 1.7 | 1.3 | 0.6 | 0.48 | 0.4 | 0.38 | 0.33 | 0.26 | 0.25 | 0.21 |
Torsion and forces | ||||||||||
| Standard ≤ 8 | Standard ≤ 10 | ||||||||
| 30 | |||||||||
| 3500 | |||||||||
| 134 | |||||||||
Temperature [°C] | ||||||||||
| + 90 | |||||||||
| -15 to +40 | |||||||||
Housing | ||||||||||
| Heat-treated steel | |||||||||
| Anthracite gray; RAL 7016 | |||||||||
| Sealed bearing disks |