NPT025 MA
Mechanical data | 1-stage | 2-stage | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 4 | 9 | 12 | 15 | 16 | 20 | 28 | 30 | 40 |
| 97 | 95 | ||||||||
| ≤ 61 | ≤ 59 | ||||||||
| > 20000 | |||||||||
| 4.4 | 4.7 | ||||||||
Mass moment of inertia J1 [kgcm²]
| ||||||||||
| --- | --- | 0.28 | 0.23 | 0.22 | 0.22 | 0.21 | 0.2 | 0.19 | 0.19 |
| --- | --- | 0.3 | 0.25 | 0.23 | 0.24 | 0.23 | 0.21 | 0.21 | 0.21 |
| 0.75 | 0.57 | 0.37 | 0.32 | 0.31 | 0.31 | 0.3 | 0.29 | 0.29 | 0.28 |
| 0.9 | 0.72 | 0.5 | 0.45 | 0.44 | 0.44 | 0.43 | 0.42 | 0.41 | 0.41 |
| 0.99 | 0.8 | 0.58 | 0.53 | 0.52 | 0.52 | 0.51 | 0.5 | 0.5 | 0.49 |
| 2 | 1.8 | --- | --- | --- | --- | --- | --- | --- | --- |
| 1.7 | 1.5 | --- | --- | --- | --- | --- | --- | --- | --- |
Torques and speeds | ||||||||||
| 185 | 185 | 185 | 185 | 185 | 185 | 185 | 185 | 168 | 185 |
| 63 | 58 | 63 | 60 | 58 | 58 | 58 | 53 | 58 | 63 |
| 125 | 115 | 125 | 125 | 120 | 115 | 115 | 115 | 105 | 115 |
| 190 | |||||||||
| 3100 | 3300 | 3300 | 3500 | 3700 | 3500 | 3700 | 4000 | 4300 | 4300 |
| 7000 | 8000 | ||||||||
| 0.43 | 0.35 | 0.16 | 0.13 | 0.12 | 0.11 | 0.1 | 0.09 | 0.08 | 0.08 |
Torsion and forces | ||||||||||
| Standard ≤ 8 | Standard ≤ 10 | ||||||||
| 12 | |||||||||
| 1900 | |||||||||
| 79 | |||||||||
Temperature [°C] | ||||||||||
| + 90 | |||||||||
| -15 to +40 | |||||||||
Housing | ||||||||||
| Heat-treated steel | |||||||||
| Anthracite gray; RAL 7016 | |||||||||
| Sealed bearing disks | |||||||||