Mounting
- 1. Carefully degrease the following components with a cloth:
- Contact surfaces with adjacent components
- Centering and motor shaft
- Internal diameter of the clamping hub
- Spacer sleeve inside and outside
In case of motor with feather key [+]
- 2. Remove feather key [+] and insert half wedge
- 3. Remove the screw plug [1] from the adapter plate [2]
- 4. Turn the clamping hub [1] until the screw [2] can be seen above the mounting hole
- 5. Loosen the screw [2] by one turn
- 6. Insert the motor shaft [1] into the clamping hub [2]
- 7. Make sure that no gap is created between the motor and the adapter plate
![]() | Do not exceed the permissible axial forces If the motor shaft cannot be inserted easily, the screw on the clamping hub must be loosened a little more. With certain motor shaft diameters, a slotted spacer sleeve must be installed in addition. If there is a groove on the motor shaft, it must be aligned with the slot in the spacer sleeve. |
This example shows a motor size with four fixing points in the flange.
- 8. Coat screws [1], [2], [3] and [4] with threadlocker
- 9. Insert bolts [1], [2], [3] and [4] and tighten evenly.
- 10. Tighten bolt [5]. Refer to the chapter Clamping hub.
- 11. Insert the screw plug back into the adapter plate