TP050 MA

Mechanical data

2-stage

3-stage

  • Ratio

22

27.5

38.5

55

66

88

110

154

220

  • Efficiency under full load ŋ [%]

94

92

  • Running noise LPA [dB]
  • at n1 = 3000 rpm without load

≤ 60

≤ 57

  • Service life Lh [h]

> 20000

  • Weight [kg]
  • Depending on the clamping hub diameter and selected adapter plate

12.5

13.4

Mass moment of inertia J1 [kgcm²]

  • Based on the drive
  • Letters = specification of the clamping hub diameter
  • G = 24 mm

3.8

3.33

3

2.8

2.6

2.4

2.2

2.1

2.1

  • K = 38 mm

10.7

10.3

9.9

9.7

---

---

---

---

---

Torques and speeds

  • Maximum torque T2a [Nm]

1402

  • Nominal output torque T2N [Nm]
  • At n1N

523

566

638

717

723

794

794

794

794

  • Maximum acceleration torque T2B [Nm]
  • Maximum 1000 cycles per hour

992

  • EMERGENCY STOP torque T2Em.stop [Nm]
  • Possible 1000 times during the service life of the gear unit

2375

  • Nominal input speed n1N [min-1]

3000

3500

  • Maximum input speed n1Max [min-1]

6250

  • Idle torque T012 [Nm]
  • Based on the drive

2.7

2.4

2.1

1.7

1.8

1.3

1.1

0.9

0.72

Torsion and forces

  • Maximum torsional backlash jt [arcmin]

≤ 1

  • Maximum torsional rigidity Ct21 [arcmin]

220

205

  • Maximum axial force F2AMax [N]
  • In relation to the shaft center at the output

6130

  • Maximum breakdown torque M2Max [Nm]

1335

  • Tilting rigidity C2K [Nm/arcmin]

560

Temperature [°C]

  • Maximum housing temperature

+ 90

  • Ambient temperature

-15 to +40

Housing

  • Properties

Heat-treated steel

  • Color

Anthracite gray; RAL 7016

  • Seal

Sealed bearing disks