TP110 MF
Mechanical data | 1-stage | ||||
---|---|---|---|---|---|
| 4 | 5 | 7 | 8 | 10 |
| 97 | ||||
| ≤ 68 | ||||
| > 20000 | ||||
| 30 | ||||
Mass moment of inertia J1 [kgcm²]
| |||||
| 44.5 | 34.6 | 25.5 | 25.5 | 20.6 |
| 58.8 | 41.9 | 32.9 | 32.9 | 28 |
| 61.5 | 51.5 | 42.3 | 42.3 | 37.3 |
Torques and speeds | |||||
| 2560 | 2560 | 2560 | 2240 | 2240 |
| 946 | 919 | 861 | 861 | 901 |
| 1920 | 1920 | 1920 | 1680 | 1680 |
| 3075 | ||||
| 1400 | 1500 | 2000 | 2000 | 2000 |
| 4500 | ||||
| 16 | 12 | 8.8 | 8.8 | 6 |
Torsion and forces | |||||
| Standard ≤ 3 / Reduced ≤ 1 | ||||
| 610 | 610 | 550 | 445 | 445 |
| 10050 | ||||
| 3280 | ||||
| 1452 | ||||
Temperature [°C] | |||||
| + 90 | ||||
| -15 to +40 | ||||
Housing | |||||
| Heat-treated steel | ||||
| Anthracite gray; RAL 7016 | ||||
| Sealed bearing disks |
Mechanical data | 2-stage | |||||||
---|---|---|---|---|---|---|---|---|
| 16 | 20 | 21 | 25 | 28 | 31 | 32 | 35 |
| 94 | |||||||
| ≤ 61 | |||||||
| > 20000 | |||||||
| 34 | |||||||
Mass moment of inertia J1 [kgcm²]
| ||||||||
| 8.51 | 8.21 | 8.98 | 7.85 | 6.57 | 8.09 | 6.57 | 6.37 |
| 11.7 | 11.4 | 12.1 | 11 | 9.73 | 11.3 | 9.73 | 9.54 |
| 12.7 | 12.5 | 13.2 | 12.1 | 10.8 | 12.3 | 10.8 | 10.6 |
| 27.4 | 27.1 | 27.8 | 26.7 | 25.4 | 26.9 | 25.4 | 25.3 |
Torques and speeds | ||||||||
| 1760 | 1760 | 1540 | 1760 | 1760 | 1760 | 1760 | 1760 |
| 1205 | 1240 | 1023 | 1278 | 1257 | 1065 | 1221 | 1408 |
| 1760 | 1760 | 1540 | 1760 | 1760 | 1760 | 1760 | 1760 |
| 3075 | |||||||
| 2500 | |||||||
| 5625 | |||||||
| 7 | 5.8 | 5.2 | 5.2 | 4.5 | 4.4 | 4.5 | 3.1 |
Torsion and forces | ||||||||
| Standard ≤ 3 / Reduced ≤ 1 | |||||||
| 585 | 580 | 465 | 570 | 560 | 440 | 560 | 560 |
| 10050 | |||||||
| 3280 | |||||||
| 1452 | |||||||
Temperature [°C] | ||||||||
| + 90 | |||||||
| -15 to +40 | |||||||
Housing | ||||||||
| Heat-treated steel | |||||||
| Anthracite gray; RAL 7016 | |||||||
| Sealed bearing disks |
Mechanical data | 2-stage | ||||||
---|---|---|---|---|---|---|---|
| 40 | 50 | 61 | 64 | 70 | 91 | 100 |
| 94 | ||||||
| ≤ 61 | ||||||
| > 20000 | ||||||
| 34 | ||||||
Mass moment of inertia J1 [kgcm²]
| |||||||
| 5.63 | 5.54 | 5.63 | 5.78 | 5.44 | 5.51 | 5.40 |
| 8.80 | 8.70 | 8.80 | 8.95 | 8.61 | 8.67 | 8.56 |
| 9.87 | 9.77 | 9.87 | 10 | 9.68 | 9.74 | 9.63 |
| 24.5 | 24.4 | 24.5 | 24.9 | 24.3 | 24.4 | 24.3 |
Torques and speeds | |||||||
| 1760 | 1760 | 1540 | 1540 | 1760 | 1430 | 1540 |
| 1315 | 1408 | 1232 | 1232 | 1408 | 1144 | 1232 |
| 1760 | 1760 | 1540 | 1540 | 1760 | 1430 | 1540 |
| 3075 | ||||||
| 2500 | 2900 | 3200 | 2900 | 3200 | 3400 | 3400 |
| 5625 | ||||||
| 3 | 2.5 | 2.1 | 2.5 | 2 | 1.8 | 1.8 |
Torsion and forces | |||||||
| Standard ≤ 3 / Reduced ≤ 1 | ||||||
| 520 | 525 | 415 | 525 | 480 | 360 | 395 |
| 10050 | ||||||
| 3280 | ||||||
| 1452 | ||||||
Temperature [°C] | |||||||
| + 90 | ||||||
| -15 to +40 | ||||||
Housing | |||||||
| Heat-treated steel | ||||||
| Anthracite gray; RAL 7016 | ||||||
| Sealed bearing disks |