TP050 MF
Mechanical data | 1-stage | ||||
|---|---|---|---|---|---|
Ratio | 4 | 5 | 7 | 8 | 10 |
Efficiency under full load ŋ [%] | 97 | ||||
Running noise LPA [dB] at n1 = 3000 rpm without load | ≤ 64 | ||||
Service life Lh [h] | > 20000 | ||||
Weight [kg] Depending on the clamping hub diameter and selected adapter plate | 14 | ||||
Mass moment of inertia J1 [kgcm²] Based on the drive Letters = specification of the clamping hub diameter | |||||
G = 24 mm | 9.47 | 7.85 | 6.39 | 6.39 | 5.54 |
I = 32 mm | 12.5 | 11 | 9.55 | 9.55 | 8.10 |
K = 38 mm | 13.7 | 12.1 | 10.6 | 10.6 | 9.78 |
M = 48 mm | 28.3 | 26.7 | 25.3 | 25.3 | 24.4 |
Torques and speeds | |||||
Maximum torque T2a [Nm] | 992 | 992 | 868 | 720 | 720 |
Nominal output torque T2N [Nm] At n1N | 345 | 337 | 322 | 316 | 331 |
Maximum acceleration torque T2B [Nm] Maximum 1000 cycles per hour | 840 | 840 | 840 | 648 | 648 |
EMERGENCY STOP torque T2Em.stop [Nm] Possible 1000 times during the service life of the gear unit | 1250 | ||||
Nominal input speed n1N [min-1] | 1900 | 2000 | 2500 | 2500 | 2500 |
Maximum input speed n1Max [min-1] | 5000 | ||||
Idle torque T012 [Nm] Based on the drive | 6.5 | 5.3 | 3.8 | 3.8 | 2.9 |
Torsion and forces | |||||
Maximum torsional backlash jt [arcmin] | Standard ≤ 3 / Reduced ≤ 1 | ||||
Maximum torsional rigidity Ct21 [Nm/arcmin] | 190 | 187 | 159 | 123 | 123 |
Maximum axial force F2AMax [N] In relation to the shaft center at the output | 6130 | ||||
Maximum breakdown torque M2Max [Nm] | 1335 | ||||
Tilting rigidity C2K [Nm/arcmin] | 560 | ||||
Temperature [°C] | |||||
Maximum housing temperature | + 90 | ||||
Ambient temperature | -15 to +40 | ||||
Housing | |||||
Properties | Heat-treated steel | ||||
Color | Anthracite gray; RAL 7016 | ||||
Seal | Sealed bearing disks | ||||
Mechanical data | 2-stage | |||||||
|---|---|---|---|---|---|---|---|---|
Ratio | 16 | 20 | 21 | 25 | 28 | 31 | 32 | 35 |
Efficiency under full load ŋ [%] | 94 | |||||||
Running noise LPA [dB] at n1 = 3000 rpm without load | ≤ 58 | |||||||
Service life Lh [h] | > 20000 | |||||||
Weight [kg] Depending on the clamping hub diameter and selected adapter plate | 14.1 | |||||||
Mass moment of inertia J1 [kgcm²] Based on the drive Letters = specification of the clamping hub diameter | ||||||||
E = 19 mm | 2.53 | 2.08 | 2.30 | 2.01 | 1.67 | 2.12 | 1.67 | 1.64 |
G = 24 mm | 3.22 | 2.77 | 2.99 | 2.70 | 2.37 | 2.81 | 2.37 | 2.33 |
K = 38 mm | 10.3 | 9.83 | 10.1 | 9.77 | 9.43 | 9.88 | 9.43 | 9.40 |
Torques and speeds | ||||||||
Maximum torque T2a [Nm] | 825 | 825 | 660 | 825 | 825 | 682 | 825 | 825 |
Nominal output torque T2N [Nm] At n1N | 461 | 493 | 393 | 489 | 545 | 431 | 464 | 541 |
Maximum acceleration torque T2B [Nm] Maximum 1000 cycles per hour | 825 | 825 | 660 | 825 | 825 | 682 | 825 | 825 |
EMERGENCY STOP torque T2Em.stop [Nm] Possible 1000 times during the service life of the gear unit | 1250 | |||||||
Nominal input speed n1N [min-1] | 2900 | |||||||
Maximum input speed n1Max [min-1] | 6250 | |||||||
Idle torque T012 [Nm] Based on the drive | 2.8 | 2.4 | 2.2 | 2.6 | 2 | 1.9 | 2 | 1.5 |
Torsion and forces | ||||||||
Maximum torsional backlash jt [arcmin] | Standard ≤ 3 / Reduced ≤ 1 | |||||||
Maximum torsional rigidity Ct21 [Nm/arcmin] | 180 | 185 | 145 | 180 | 180 | 130 | 180 | 175 |
Maximum axial force F2AMax [N] In relation to the shaft center at the output | 6130 | |||||||
Maximum breakdown torque M2Max [Nm] | 1335 | |||||||
Tilting rigidity C2K [Nm/arcmin] | 560 | |||||||
Temperature [°C] | ||||||||
Maximum housing temperature | + 90 | |||||||
Ambient temperature | -15 to +40 | |||||||
Housing | ||||||||
Properties | Heat-treated steel | |||||||
Color | Anthracite gray; RAL 7016 | |||||||
Seal | Sealed bearing disks | |||||||
Mechanical data | 2-stage | ||||||
|---|---|---|---|---|---|---|---|
Ratio | 40 | 50 | 61 | 64 | 70 | 91 | 100 |
Efficiency under full load ŋ [%] | 94 | ||||||
Running noise LPA [dB] at n1 = 3000 rpm without load | ≤ 58 | ||||||
Service life Lh [h] | > 20000 | ||||||
Weight [kg] Depending on the clamping hub diameter and selected adapter plate | 14.1 | ||||||
Mass moment of inertia J1 [kgcm²] Based on the drive Letters = specification of the clamping hub diameter | |||||||
E = 19 mm | 1.44 | 1.42 | 1.46 | 1.51 | 1.41 | 1.43 | 1.40 |
G = 24 mm | 2.13 | 2.12 | 2.15 | 2.20 | 2.10 | 2.12 | 2.09 |
K = 38 mm | 9.20 | 9.18 | 9.22 | 9.50 | 9.17 | 9.19 | 9.16 |
Torques and speeds | |||||||
Maximum torque T2a [Nm] | 825 | 825 | 605 | 594 | 770 | 550 | 594 |
Nominal output torque T2N [Nm] At n1N | 607 | 585 | 425 | 475 | 598 | 440 | 475 |
Maximum acceleration torque T2B [Nm] Maximum 1000 cycles per hour | 825 | 825 | 605 | 594 | 770 | 550 | 594 |
EMERGENCY STOP torque T2Em.stop [Nm] Possible 1000 times during the service life of the gear unit | 1250 | ||||||
Nominal input speed n1N [min-1] | 2900 | 3200 | 3200 | 3200 | 3200 | 3900 | 3900 |
Maximum input speed n1Max [min-1] | 6250 | ||||||
Idle torque T012 [Nm] Based on the drive | 1.5 | 1.2 | 1 | 1.2 | 1.1 | 0.96 | 0.88 |
Torsion and forces | |||||||
Maximum torsional backlash jt [arcmin] | Standard ≤ 3 / Reduced ≤ 1 | ||||||
Maximum torsional rigidity Ct21 [Nm/arcmin] | 175 | 175 | 123 | 175 | 145 | 100 | 115 |
Maximum axial force F2AMax [N] In relation to the shaft center at the output | 6130 | ||||||
Maximum breakdown torque M2Max [Nm] | 1335 | ||||||
Tilting rigidity C2K [Nm/arcmin] | 560 | ||||||
Temperature [°C] | |||||||
Maximum housing temperature | + 90 | ||||||
Ambient temperature | -15 to +40 | ||||||
Housing | |||||||
Properties | Heat-treated steel | ||||||
Color | Anthracite gray; RAL 7016 | ||||||
Seal | Sealed bearing disks | ||||||