TP004 MF
Mechanical data | 1-stage | ||||
|---|---|---|---|---|---|
Ratio | 4 | 5 | 7 | 8 | 10 |
Efficiency under full load ŋ [%] | 97 | ||||
Running noise LPA [dB] at n1 = 3000 rpm without load | ≤ 55 | ||||
Service life Lh [h] | > 20000 | ||||
Weight [kg] Depending on the clamping hub diameter and selected adapter plate | 1.4 | ||||
Mass moment of inertia J1 [kgcm²] Based on the drive Letters = specification of the clamping hub diameter | |||||
B = 11 mm | 0.17 | 0.14 | 0.11 | 0.11 | 0.09 |
C = 14 mm | 0.25 | 0.21 | 0.18 | 0.18 | 0.17 |
E = 19 mm | 0.57 | 0.54 | 0.51 | 0.51 | 0.49 |
Torques and speeds | |||||
Maximum torque T2a [Nm] | 83 | 83 | 83 | 56 | 56 |
Nominal output torque T2N [Nm] At n1N | 27 | 27 | 26 | 26 | 27 |
Maximum acceleration torque T2B [Nm] Maximum 1000 cycles per hour | 66 | 66 | 66 | 42 | 42 |
EMERGENCY STOP torque T2Em.stop [Nm] Possible 1000 times during the service life of the gear unit | 100 | ||||
Nominal input speed n1N [min-1] | 3300 | 3300 | 4000 | 4000 | 4000 |
Maximum input speed n1Max [min-1] | 7500 | ||||
Idle torque T012 [Nm] Based on the drive | 0.56 | 0.48 | 0.37 | 0.37 | 0.31 |
Torsion and forces | |||||
Maximum torsional backlash jt [arcmin] | Standard ≤ 4 / Reduced ≤ 2 | ||||
Maximum torsional rigidity Ct21 [Nm/arcmin] | 12 | 12 | 11 | 8 | 8 |
Maximum axial force F2AMax [N] In relation to the shaft center at the output | 2119 | ||||
Maximum breakdown torque M2Max [Nm] | 110 | ||||
Tilting rigidity C2K [Nm/arcmin] | 85 | ||||
Temperature [°C] | |||||
Maximum housing temperature | + 90 | ||||
Ambient temperature | -15 to +40 | ||||
Housing | |||||
Properties | Heat-treated steel | ||||
Color | Anthracite gray; RAL 7016 | ||||
Seal | Sealed bearing disks | ||||
Mechanical data | 2-stage | |||||||
|---|---|---|---|---|---|---|---|---|
Ratio | 16 | 20 | 21 | 25 | 28 | 31 | 32 | 35 |
Efficiency under full load ŋ [%] | 94 | |||||||
Running noise LPA [dB] at n1 = 3000 rpm without load | ≤ 54 | |||||||
Service life Lh [h] | > 20000 | |||||||
Weight [kg] Depending on the clamping hub diameter and selected adapter plate | 1.5 | |||||||
Mass moment of inertia J1 [kgcm²] Based on the drive Letters = specification of the clamping hub diameter | ||||||||
B = 11 mm | 0.078 | 0.070 | 0.074 | 0.068 | 0.062 | 0.072 | 0.062 | 0.061 |
C = 14 mm | 0.17 | 0.17 | 0.17 | 0.16 | 0.16 | 0.17 | 0.16 | 0.16 |
Torques and speeds | ||||||||
Maximum torque T2a [Nm] | 57 | 57 | 60 | 72 | 57 | 50 | 57 | 72 |
Nominal output torque T2N [Nm] At n1N | 39 | 41 | 32 | 41 | 45 | 36 | 39 | 45 |
Maximum acceleration torque T2B [Nm] Maximum 1000 cycles per hour | 57 | 57 | 48 | 66 | 57 | 48 | 57 | 66 |
EMERGENCY STOP torque T2Em.stop [Nm] Possible 1000 times during the service life of the gear unit | 100 | |||||||
Nominal input speed n1N [min-1] | 4000 | |||||||
Maximum input speed n1Max [min-1] | 7500 | |||||||
Idle torque T012 [Nm] Based on the drive | 0.28 | 0.23 | 0.24 | 0.22 | 0.21 | 0.22 | 0.21 | 0.17 |
Torsion and forces | ||||||||
Maximum torsional backlash jt [arcmin] | Standard ≤ 4 / Reduced ≤ 2 | |||||||
Maximum torsional rigidity Ct21 [Nm/arcmin] | 12 | 12 | 10 | 12 | 12 | 9 | 12 | 12 |
Maximum axial force F2AMax [N] In relation to the shaft center at the output | 2119 | |||||||
Maximum breakdown torque M2Max [Nm] | 110 | |||||||
Tilting rigidity C2K [Nm/arcmin] | 85 | |||||||
Temperature [°C] | ||||||||
Maximum housing temperature | + 90 | |||||||
Ambient temperature | -15 to +40 | |||||||
Housing | ||||||||
Properties | Heat-treated steel | |||||||
Color | Anthracite gray; RAL 7016 | |||||||
Seal | Sealed bearing disks | |||||||
Mechanical data | 2-stage | ||||||
|---|---|---|---|---|---|---|---|
Ratio | 40 | 50 | 61 | 64 | 70 | 91 | 100 |
Efficiency under full load ŋ [%] | 95 | ||||||
Running noise LPA [dB] at n1 = 3000 rpm without load | ≤ 54 | ||||||
Service life Lh [h] | > 20000 | ||||||
Weight [kg] Depending on the clamping hub diameter and selected adapter plate | 1.5 | ||||||
Mass moment of inertia J1 [kgcm²] Based on the drive Letters = specification of the clamping hub diameter | |||||||
B = 11 mm | 0.057 | 0.057 | 0.058 | 0.060 | 0.056 | 0.057 | 0.056 |
C = 14 mm | 0.15 | 0.15 | 0.15 | 0.16 | 0.15 | 0.15 | 0.15 |
Torques and speeds | |||||||
Maximum torque T2a [Nm] | 57 | 72 | 49 | 48 | 56 | 43 | 48 |
Nominal output torque T2N [Nm] At n1N | 46 | 48 | 39 | 34 | 45 | 31 | 34 |
Maximum acceleration torque T2B [Nm] Maximum 1000 cycles per hour | 57 | 66 | 49 | 42 | 56 | 38 | 42 |
EMERGENCY STOP torque T2Em.stop [Nm] Possible 1000 times during the service life of the gear unit | 100 | ||||||
Nominal input speed n1N [min-1] | 4000 | 4800 | 5500 | 4800 | 5500 | 5500 | 5500 |
Maximum input speed n1Max [min-1] | 7500 | ||||||
Idle torque T012 [Nm] Based on the drive | 0.18 | 0.17 | 0.16 | 0.17 | 0.17 | 0.15 | 0.16 |
Torsion and forces | |||||||
Maximum torsional backlash jt [arcmin] | Standard ≤ 4 / Reduced ≤ 2 | ||||||
Maximum torsional rigidity Ct21 [Nm/arcmin] | 11 | 12 | 9 | 12 | 11 | 7 | 8 |
Maximum axial force F2AMax [N] In relation to the shaft center at the output | 2119 | ||||||
Maximum breakdown torque M2Max [Nm] | 110 | ||||||
Tilting rigidity C2K [Nm/arcmin] | 85 | ||||||
Temperature [°C] | |||||||
Maximum housing temperature | + 90 | ||||||
Ambient temperature | -15 to +40 | ||||||
Housing | |||||||
Properties | Heat-treated steel | ||||||
Color | Anthracite gray; RAL 7016 | ||||||
Seal | Sealed bearing disks | ||||||