SP210 MF
Mechanical data | 1-stage | |||||
|---|---|---|---|---|---|---|
| 3 | 4 | 5 | 7 | 8 | 10 |
| 97 | |||||
| ≤ 64 | |||||
| > 20000 | |||||
| 56 | |||||
Mass moment of inertia J1 [kgcm²]
| ||||||
| 139 | 94.30 | 76.90 | 61.50 | 61.50 | 53.10 |
Torques and speeds | ||||||
| 1536 | 1895 | 1767 | 1731 | 1631 | 1708 |
| 1920 | 3000 | 2880 | 2280 | ||
| 5900 | |||||
| 1200 | 1500 | 1700 | 2000 | ||
| 3000 | |||||
| 26 | 19 | 15 | 8.80 | 8.80 | 6.40 |
Torsion and forces | ||||||
| Standard ≤ 3 / Reduced ≤ 1 | |||||
| 400 | |||||
| 30000 | |||||
| 21000 | |||||
| 3100 | |||||
Temperature [°C] | ||||||
| + 90 | |||||
| -15 to +40 | |||||
Housing | ||||||
| Heat-treated steel | |||||
| Anthracite gray; RAL 7016 | |||||
| Sealed bearing discs | |||||
Mechanical data | 2-stage | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 16 | 20 | 25 | 28 | 32 | 35 | 40 | 50 | 64 | 70 | 100 |
| 94 | ||||||||||
| ≤ 57 | ||||||||||
| > 20000 | ||||||||||
| 53 | ||||||||||
Mass moment of inertia J1 [kgcm²]
| |||||||||||
| 34.50 | 31.50 | 30.80 | 30 | 29.70 | 28.50 | 28.30 | 28.10 | 28 | ||
Torques and speeds | |||||||||||
| 1274 | 1266 | 1567 | 1294 | 2200 | 1599 | 1358 | 1679 | 1634 | 1965 | 1634 |
| 2880 | 3000 | 2880 | 2840 | 2880 | 2043 | 2457 | 2043 | |||
| 5900 | ||||||||||
| 2500 | 3000 | |||||||||
| 4500 | ||||||||||
| 5.60 | 5.20 | 4.80 | 4.50 | 3.60 | 3.40 | 3 | 3 | 2.60 | 2.40 | |
Torsion and forces | |||||||||||
| Standard ≤ 5 / Reduced ≤ 3 | ||||||||||
| 400 | ||||||||||
| 30000 | ||||||||||
| 21000 | ||||||||||
| 3100 | ||||||||||
Temperature [°C] | |||||||||||
| + 90 | ||||||||||
| -15 to +40 | ||||||||||
Housing | |||||||||||
| Heat-treated steel | ||||||||||
| Anthracite gray; RAL 7016 | ||||||||||
| Sealed bearing discs | ||||||||||