Mounting the gear
Order of assembly:
- Clean the motor shaft and the sun wheel with isopropanol. Remove all dirt particles from the motor shaft or sun wheel. Carefully dry all the components.
- Wet the sun wheel and the motor shaft with the adhesive WEICONLOCK AN 306-60. Make sure that the adhesive is evenly distributed over the complete motor shaft.
- NoteDamage to the gear unit!
When wetting the motor shaft, make sure that no adhesive runs into the interior of the component! There is a danger of components sticking and impairing the function of the gear unit!

Hardening time of the adhesive!
WEICONLOCK AN 306-60 is an anaerobic adhesive. It hardens immediately on contact with metal and the exclusion of oxygen. Note that the components can no longer be moved after gluing. The adhesive is completely hardened after 10 to 15 minutes.
- Now wet the threaded holes of the gear unit with a screw-locking compound. Make sure that all threads are completely wetted.
- Push the motor onto the gear unit and fix both components.
- Now fasten the gear unit to the motor with the four hex socket-head screws. Tighten the screws diagonally. Observe the specified tightening torque.