Important notes
CAUTION
Damage to persons and devices
Observe the general and special safety instructions.
The gear unit can be used in any gear unit.
Note
Assembly sequence
Always follow the assembly sequence described below in order to avoid damage.
The fastening screws are not included and must be provided by the customer. Pertinent information can be found in the individual assembly steps.
Note
Compressed air may damage gear unit seals.
Do not use compressed air for cleaning the gear unit.
Note
In rare cases, leaks ("sweating") may occur at the drive in gear units with grease lubrication (see type plate).
- To avoid "sweating", we recommend sealing the areas between
- adapter plate, drive housing and gear unit and
- adapter plate and motor
- with a surface seal adhesive (e.g. Loctite® 573 or 574).
- For further information please contact our customer service.
- Clean the following components with a clean, lint-free cloth and a grease-dissolving, non-aggressive cleaning agent:
- all surfaces in contact with adjacent components
- Centering
- the motor shaft
- the internal diameter of the socket
- the spacer sleeve inside and outside
- In addition, check the contact surfaces for damage and foreign particles.