- Planetary gear unit AG1000-+PMxx - Version 1.4
- Technical description
- Transport, assembly and disassembly
Transport, assembly and disassembly
 | Recommendations for trouble-free operation and long service life
- Ensure adequate convection of the gear unit.
- Ensure adequate heat dissipation from the gear unit via the output flange.
- The gear unit may heat up due to the motor and other external heat sources. Acquaint yourself with the motor temperature and external influences that may occur during operation.
- Note the protection class of the gear unit and the resulting constraints.
|
Preparing the installation
The drive and output sides are treated with a corrosion inhibitor to protect from corrosion. Ensure that the installation instructions are enclosed with the gear unit and remove the corrosion inhibitor, once you have read up on handling hazardous substances.