Storage

  • The gear units must not be stored outdoors. The storage space must be adequately ventilated and dry.
  • The gear units may only be stored in the original recyclable manufacturer's packaging.
  • The gear units may only be stored in a horizontal position.
  • Storage temperature: -30 °C to +60 °C in the original packaging
  • Storage time: 2 years max.

Possible damage to the gear unit seals

If the gear units are stored at temperature ranges above 60 °C or subjected to direct sunlight or ultraviolet light, the gear unit seals may become damaged. Storage temperatures of up to 85 °C are permitted for a maximum of 2 weeks. However, please note that even short-term storage at such temperatures will result in premature ageing of the seals. Therefore, please check the seals before commissioning the gear unit.