1 x 230 V, 50 Hz
Rated input voltage UN= 1 x 230 V, rated input frequency fN = 50 Hz
(1) | Power losses in % of the rated output certificate power (relative motor stator frequency vs. relative torque generating current) | (0;25) | 2.22 | 1.63 | 1.62 | 2.34 | 2.24 |
(0;50) | 2.21 | 1.82 | 1.85 | 2.41 | 2.28 | ||
(0;100) | 2.55 | 2.70 | 2.40 | 2.86 | 2.71 | ||
(50;25) | 2.55 | 1.95 | 1.93 | 2.88 | 2.96 | ||
(50;50) | 2.59 | 2.39 | 2.28 | 2.94 | 3.02 | ||
(50;100) | 3.20 | 3.33 | 3.32 | 3.61 | 3.71 | ||
(90;50) | 3.00 | 3.26 | 3.28 | 3.47 | 3.69 | ||
(90;100) | 3.78 | 4.46 | 4.83 | 4.99 | 4.63 | ||
Losses in standby mode | % | 0.68 | 0.31 | 0.19 | 0.63 | 0.35 | |
W | 5.00 | 5.00 | 5.00 | 5.00 | 5.00 | ||
(2) | Efficiency level |
| IE2 | IE2 | IE2 | IE2 | IE2 |
(3) | Vendor name | Beckhoff Automation GmbH & Co. KG Hülshorstweg 20 33415 Verl Germany | |||||
| Commercial register number | Gütersloh HRA 7075 | |||||
(4) | Model identifier |
| AF1103 -1x00 | AF1107 -1x00 | AF1115 -1x00 | AF1203 -1x00 | AF1207 -1x00 |
(5) | Output apparent power | kVA | 0.750 | 1.50 | 2.44 | 0.750 | 1.35 |
(6) | Indicative rated output power PN | kW | 0.375 | 0.750 | 1.50 | 0.375 | 0.750 |
(7) | Rated output current | A | 2.0 | 4.0 | 6.5 | 2.0 | 3.6 |
(8) | Maximum operating temperature | °C | 55 | ||||
(9) | Rated input frequency | Hz | 50 | ||||
(10) | Rated input voltage | V | 1 x 110 V AC-15% ... 240 V AC+10% | ||||
| Switching frequency | kHz | 4 | 4 | 4 | 4 | 4 |