Disassembly
| |
Risk of injury due to unintentional machine movement Unintentional machine movements can lead to serious or fatal injuries.
|
![]() | Do not remove components from the products Only Beckhoff Automation GmbH & Co. KG is permitted to remove components. Contact Beckhoff Service for further information. |
Removal of the electric cylinder from the machine
- ►Allow the electric cylinder to cool down before removing it.
- ►Remove cables and electrical connections.
- ►Establish a safe condition of the machine.
- ►Secure the machine against unintentional movements by releasing the electric cylinder.
- ►If lubricants leak out, remove them and clean the working area of the spindle. Further information can be found in chapter Cleaning.
- ►Loosen the connection of the spindle end with the application and remove all screwed-on connecting elements from the housing. Then remove the electric cylinder.
- ►Transport the electric cylinder to the workplace or storage place. Further information can be found in chapter Transport and storage.