Disassembly

WARNING

Risk of injury due to unintentional machine movement

Unintentional machine movements can lead to serious or fatal injuries.

  • For disassembly, make sure that the machine is de-energized and secured. Particularly in the case of vertical axes, machine parts can start moving unintentionally after the electric cylinder has been released.
Disassembly 1:

Do not remove components from the products

Only Beckhoff Automation GmbH & Co. KG is permitted to remove components.

Contact Beckhoff Service for further information.

Removal of the electric cylinder from the machine

►Allow the electric cylinder to cool down before removing it.
►Remove cables and electrical connections.
►Establish a safe condition of the machine.
►Secure the machine against unintentional movements by releasing the electric cylinder.
►If lubricants leak out, remove them and clean the working area of the spindle. Further information can be found in chapter Cleaning.
►Loosen the connection of the spindle end with the application and remove all screwed-on connecting elements from the housing. Then remove the electric cylinder.
►Transport the electric cylinder to the workplace or storage place. Further information can be found in chapter Transport and storage.