Select motor cables

For faster and error-free installation of the electric cylinders, use the recommended pre-assembled motor cables according to the servo drive used. The use of other cables can cause unexpected faults and result in exclusion of warranty.

Further selection aids can be found in the line selection wizard of the TwinCAT 3 Motion Designer, on the accessories overview for drive components and on the product web pages of the electric cylinder.

Select motor cables 1:

Selection of the motor cables

The cable selection wizard of the TwinCAT 3 Motion Designer for drive design displays the suitable cables corresponding to the set components of the axis. The integrated parts list generator also lists the necessary accessory components such as motor cables, chokes and mounting material.

TE5910 | TwinCAT 3 Motion Designer

Select motor cables 2:

Define cable length via order specifications

The last four digits of the order code correspond to the cable length in decimeters: A ZK4xxx-xxxx-0020 cable is 2.00 m long.

Motor cables for ELM72xx Servomotor EtherCAT Terminals

AA3123, AA3133

Servo drive

Ordering information

Laying method

ELM7211 to ELM7231

ZK4704-0401-2xxx

Fixed installation

ZK4704-0421-2xxx

Highly dynamic

ZK4704-0461-2xxx

Torsion-capable

Select motor cables 3:

The maximum cable length for the ELM72xx is limited to a maximum of 20 m OCT cable including extension.