Select motor cables
For faster and error-free installation of the electric cylinders, use the recommended pre-assembled motor cables according to the servo drive used. The use of other cables can cause unexpected faults and result in exclusion of warranty.
Further selection aids can be found in the line selection wizard of the TwinCAT 3 Motion Designer, on the accessories overview for drive components and on the product web pages of the electric cylinder.
![]() | Selection of the motor cables The cable selection wizard of the TwinCAT 3 Motion Designer for drive design displays the suitable cables corresponding to the set components of the axis. The integrated parts list generator also lists the necessary accessory components such as motor cables, chokes and mounting material. |
![]() | Define cable length via order specifications The last four digits of the order code correspond to the cable length in decimeters: A ZK4xxx-xxxx-0020 cable is 2.00 m long. |
Motor cables for ELM72xx Servomotor EtherCAT Terminals
AA3123, AA3133
Servo drive | Ordering information | Laying method |
|---|---|---|
ELM7211 to ELM7231 | ZK4704-0401-2xxx | Fixed installation |
ZK4704-0421-2xxx | Highly dynamic | |
ZK4704-0461-2xxx | Torsion-capable |
![]() | The maximum cable length for the ELM72xx is limited to a maximum of 20 m OCT cable including extension. |