Flange mounting
The electric cylinder can be mounted in the machine or system on the A-flange and/or on the B-flange.
For this purpose, the electric cylinder has four mounting holes per flange side to accommodate hexagon socket head cap screw. The dimensions of the screws to be used depends on the size.
The following table shows the screw size, the corresponding screw depths and the tightening torques.
Size | AA3123 | AA3133 |
|---|---|---|
Hexagon socket head cap screw DIN EN ISO 4762–8.8 | M6 | M8 |
A-flange screw depth [mm] | 10 | 30 |
B-flange screw depth [mm] | 20 | 25 |
Tightening torque [Nm] | 10 | 24 |
Notice | |
Encoder signal fault Insufficient or missing grounding of the electric cylinder can lead to interference of the encoder signals.
|