Maintenance intervals
Under nominal conditions, the electric cylinder components have different operating hours. We have provided you with a list of maintenance work and intervals for the associated components below:
Component | Interval | Maintenance type |
|---|---|---|
Ball screw | Monthly | Check for running noises As the volume increases:
|
Ball screw | 1 million cycles | Lubricate the spindle drive. See chapter Lubrication of the spindle drive. |
Ball screw and ball bearing | 10 million cycles | Check for running noises As the volume increases:
|
Cables | Regular intervals | Perform visual inspection and check for damage If required:
|
5 million bending cycles | In case of drag chain suitable application:
| |
Power box | 500 mating cycles | In case of damage:
|
Connector | 10 turning cycles | In case of damage:
|