Power derating

Power derating may be necessary at high ambient temperature or when operating at a great height above sea level. Continuous forces are affected by the reduction.

Power derating 1:
Power data when exceeding the specified temperature limit

Ambient temperature

fT = Temperature utilization factor

tA = Ambient temperature in °C

Calculation of the power data when exceeding the specified temperature limit > 40 °C:

FCA_red = FC x fT

Power derating 2:
Power data when exceeding the specified installation altitude

Installation altitude

fH = Altitude utilization factor

h = Altitude in meters

Calculation of the performance data if the specified installation altitude is exceeded > 1000 m above sea level:

FCA_red = FC x fH

Calculation of the power reduction

Ambient temperature and installation altitude

Calculation of the power data when exceeding the specified limits:

Ambient temperature > 40 °C and installation altitude > 1000 m above sea level:
FCA_red = FC x fT x fH