Power derating
Power derating may be necessary at high ambient temperature or when operating at a great height above sea level. Continuous forces are affected by the reduction.
Ambient temperature
fT = Temperature utilization factor
tA = Ambient temperature in °C
Calculation of the power data when exceeding the specified temperature limit > 40 °C:
FCA_red = FC x fT
Installation altitude
fH = Altitude utilization factor
h = Altitude in meters
Calculation of the performance data if the specified installation altitude is exceeded > 1000 m above sea level:
FCA_red = FC x fH
Calculation of the power reduction
Ambient temperature and installation altitude
Calculation of the power data when exceeding the specified limits:
Ambient temperature > 40 °C and installation altitude > 1000 m above sea level:
FCA_red = FC x fT x fH