Cleaning
| |
Carrying out cleaning work during operation can lead to serious or fatal injuries Basically, electronic devices are not fail-safe.
|
Notice | |
Extreme soiling can lead to failure Contamination, dust or chips can have a negative effect on the function of the components.
|
Notice | |
Damage to the electric cylinder Penetration of cleaning liquid into the electric cylinder by dipping or spraying can result in damage to the electric cylinder.
|
Housing
Clean the housing components carefully with a damp cloth or a brush. Excess grease or soiling can be wiped off with a dry, lint-free cloth. Use grease-dissolving and non-aggressive cleaning agents for cleaning. Isopropanol cleaning agent can be used for cleaning.
Non-approved cleaning agents:
Non-approved cleaning agents | Chemical formula |
|---|---|
Aniline hydrochloride | C6H5NH2HCI |
Bromine | Br2 |
Sodium hypochlorite; bleaching solution | NaCIO |
Mercury (II) chloride | HgCl2 |
Hydrochloric acid | HCI |
Output rod

The output rod must remain free of cleaning agents. If necessary, excess grease or oil can be wiped off with a lint-free cloth.
- Avoid contact with cleaning agents.
- Do not use any cleaning agents that may adhere to the spindle thread and enter the electric cylinder or the spindle nut during the working stroke.
- In the case of vertical installation, ensure that there is no cleaning agent on the cylinder opening.
