Power box
Notice | |
Wear and limited data transmission The power box may be rotated up to ten times through 330° to bring it into a safe indexing position. If you turn the power box more than ten times, the cables inside and the latching mechanism of the power box may be damaged and the power box may no longer be moved to a safe indexing position.
|
The electric cylinder has OCT (One Cable Technology) and is connected to the power box with a motor cable. The power box combines the power supply and the feedback signals. It is designed as an angle box and can be rotated by 330°.
Design of the power box on the electric cylinder
The type of power box depends on the size or peak current of the electric cylinder.
Size | Power box |
---|---|
AA3023 | rotatable angle box itec® |
AA3033 | rotatable angle box itec® |
AA3053 | rotatable angle box M23-speedtec® |