201B, On the II. connection in state CONNECTION a FSoE-Reset with Error-Code 11 was received which means that the communication partner has received invalid application parameter data
|
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
|---|---|
|
201B |
8219 |
|
Class |
Type |
|---|---|
|
Error |
Safety Module error |
|
Standard Reaction |
Reset |
|---|---|
|
No |
A reset is not possible. The drive detected a fatal hard- or software error. |